N-溴代琥珀酰亚胺-二氯荧光素化学发光体系测定废水中5-磺基水杨酸
引用本文:樊雪梅,王书民,李倩,王香婷,王宪生,陈凤英. N-溴代琥珀酰亚胺-二氯荧光素化学发光体系测定废水中5-磺基水杨酸[J]. 应用化学, 2013, 30(4): 469-473. DOI: 10.3724/SP.J.1095.2013.20246
作者姓名:樊雪梅  王书民  李倩  王香婷  王宪生  陈凤英
作者单位:(商洛学院化学与化学工程系 商洛 726000)
摘    要:建立了测定5-磺基水杨酸的流动注射化学发光新方法。 研究了影响化学发光强度的因素,并初步探讨了可能的发光机理。 在最佳化学发光条件下,化学发光强度与5-磺基水杨酸浓度在5.0×10-8~2.0×10-5 mol/L范围内呈良好的线性关系,检出限为1.0×10-8 mol/L,对5.0×10-6 mol/L的5-磺基水杨酸平行测定9次,其相对标准偏差为2.7%。 该法可用于强力霉素废水中5-磺基水杨酸的测定。

关 键 词:流动注射  化学发光  二氯荧光素  磺基水杨酸  
收稿时间:2012-06-05
修稿时间:2012-08-04

Determination of 5-Sulfosalicylic Acid in the Waste Water by NBS-Dichlorofluoresce in Chemiluminescence System
FAN Xuemei , WANG Shumin , LI Qian , WANG Xiangting , WANG Xiansheng , CHEN Fengying. Determination of 5-Sulfosalicylic Acid in the Waste Water by NBS-Dichlorofluoresce in Chemiluminescence System[J]. Chinese Journal of Applied Chemistry, 2013, 30(4): 469-473. DOI: 10.3724/SP.J.1095.2013.20246
Authors:FAN Xuemei    WANG Shumin    LI Qian    WANG Xiangting    WANG Xiansheng    CHEN Fengying
Affiliation:(Department of Chemistry and Chemical Engineering,Shangluo College,Shanxi Shangluo 726000,China)
Abstract:A new flow-injection chemiluminescence method for the determination of 5-sulfosalicylic acid was proposed. Various factors affected the chemiluminescence signal were investigated and the possible mechanism was also studied. Under the optimum conditions, the linear range for the determination of 5-sulfosalicylic acid was 5.0×10-8~2.0×10-5 mol/L with a detection limit(S/N=3) of 1.0×10-8 mol/L. The relative standard deviation was 2.7% for 5.0×10-6 mol/L 5-sulfosalicylic acid solution in nine repeated measurements. The method was successfully applied to the determination of 5-sulfosalicylic acid in the waste water of doxycycline.
Keywords:flow-injection  chemiluminescence  Dichlorofluorescein  sulfosalicylic acid
本文献已被 CNKI 万方数据 等数据库收录!