首页 | 本学科首页   官方微博 | 高级检索  
     


Calibration for stereo vision system based on phase matching and bundle adjustment algorithm
Affiliation:1. Beihang University, School of Instrumentation Science and Opto-electronics Engineering, XueYuan Road No. 37, HaiDian District, Beijing 100191, China;2. Key Laboratory of Technology and Application for Safeguarding of Marine Rights and Interests, SOA, Guangzhou 510301, China;1. School of Physics, Shandong University, Jinan 250100, China;2. Department of Engineering Mechanics, Dalian University of Technology, Dalian 116024, China;1. Jiangsu Key Laboratory of Spectral Imaging & Intelligent Sense, Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210094, China;2. Key Laboratory of Photoelectronic Imaging Technology and System, Ministry of Education of China. Beijing Institute of Technology, Beijing 100081, China
Abstract:Calibration for stereo vision system plays an important role in the field of machine vision applications. The existing accurate calibration methods are usually carried out by capturing a high-accuracy calibration target with the same size as the measurement view. In in-situ 3D measurement and in large field of view measurement, the extrinsic parameters of the system usually need to be calibrated in real-time. Furthermore, the large high-accuracy calibration target in the field is a big challenge for manufacturing. Therefore, an accurate and rapid calibration method in the in-situ measurement is needed. In this paper, a novel calibration method for stereo vision system is proposed based on phase-based matching method and the bundle adjustment algorithm. As the camera is usually mechanically locked once adjusted appropriately after calibrated in lab, the intrinsic parameters are usually stable. We emphasize on the extrinsic parameters calibration in the measurement field. Firstly, the matching method based on heterodyne multi-frequency phase-shifting technique is applied to find thousands of pairs of corresponding points between images of two cameras. The large amount of pairs of corresponding points can help improve the accuracy of the calibration. Then the method of bundle adjustment in photogrammetry is used to optimize the extrinsic parameters and the 3D coordinates of the measured objects. Finally, the quantity traceability is carried out to transform the optimized extrinsic parameters from the 3D metric coordinate system into Euclid coordinate system to obtain the ultimate optimal extrinsic parameters. Experiment results show that the procedure of calibration takes less than 3 s. And, based on the stereo vision system calibrated by the proposed method, the measurement RMS (Root Mean Square) error can reach 0.025 mm when measuring the calibrated gauge with nominal length of 999.576 mm.
Keywords:Camera calibration  Extrinsic parameters calibration  3D measurement  Phase matching  Bundle adjustment
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号