首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fracture strength for a high strength steel bridge cable wire with a surface crack
Authors:KM Mahmoud  
Institution:aBridge Technology Consulting, 295 Madison Avenue, Suite 901, New York, NY 10017, United States
Abstract:In this paper, the fracture strength of a cracked suspension bridge wire is determined based on linear elastic fracture mechanics (LEFM). The wire is 5 mm in diameter, with an original ultimate strength of 1725 MPa and ultimate elongation that ranges between 5.5% and 6%. The average value of View the MathML source for the wire fracture toughness, KC, was recently evaluated by the author. The state of practice is to use the ultimate strength of the cracked wire as obtained from tensile tests. This approach may overestimate the strength of the wire due to possible delamination and crack tip plasticity. A case study for a group of in situ wire breaks retrieved from a suspension bridge cable is presented. The failure analysis is performed based on both the fracture toughness criterion and the net section theory. The fracture toughness criterion produced more realistic results for the fracture strength of the wire. The decline in the fracture toughness and the corresponding reduction in the fracture strength of cracked degraded wire are predicted making use of the strain energy density criterion.
Keywords:Suspension bridge cable wire  Fracture toughness of bridge wire  Wire fracture strength  Cracked bridge wire  Broken bridge wire  Fracture toughness criterion  Net section theory  Hydrogen embrittlement  Stress corrosion cracking
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏