首页 | 本学科首页   官方微博 | 高级检索  
     


Calibration of hot-wire probes using non-uniform mean velocity profiles
Authors:Andrew Johnstone  Mesbah Uddin  Andrew Pollard
Affiliation:(1) Department of Mechanical and Materials Engineering, Queen"rsquo"s University, Kingston, ON, K7L 3N6, Canada
Abstract:A simple iterative procedure is illustrated here to overcome two problems frequently encountered in hot-wire anemometry: (1) the calibration of hot wires at low velocity and (2) to account for the wall-proximity correction in the actual measurements. The low-velocity calibration method used an iterative correction procedure based on laminar pipe velocity profiles. It is shown that the use of this approach, together with a simple wall proximity correction procedure, provides a simple and accurate calibration of both single and cross hot wires, and gives reliable measurements.
Keywords:
本文献已被 SpringerLink 等数据库收录!