首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of luxabendazole in biological fluids by high-performance liquid chromatography.
Authors:M L Alvarez-Bujidos  A Ortiz  R Bala?a  J C Cubría  D Ordo?ez  A Negro
Affiliation:Departamento de Fisiología, Farmacologia y Toxicología, Universidad de León, Spain.
Abstract:Luxabendazole, a new benzimidazole, is a highly potent broad-spectrum anthelmintic. A high-performance liquid chromatographic method has been developed for its determination in serum and urine samples. In order to optimize the clean-up of samples we compared two procedures: C18 Sep-Pak cartridges and ultrafiltration through a cellulose membrane with a 30,000 relative molecular mass cut-off. In order to obtain the most suitable mobile phase, we studied the influence of pH and acetonitrile content on the capacity factor (k'). Chromatographic separation and quantification were performed on a reversed-phase column packed with 5-microns Nucleosil C18. The mobile phase was acetonitrile-0.05 M phosphate buffer (pH 7.0), (40:60, v/v). The column effluent was monitored by ultraviolet-visible spectrophotometry at 290 nm. The method shows good recovery, precision and accuracy. The lower limit of detection for luxabendazole is 15 ng/ml in serum samples and 25 ng/ml in urine samples.
Keywords: