Electrothermal atomic absorption spectrometric determination of lead in high-purity reagents with flow-injection on-line microcolumn preconcentration and separation using a macrocycle immobilized silica gel sorbent
Authors:Michael Sperling  Xiu-ping Yan  Bernhard Welz
Institution:

Department of Applied Research, Bodenseewerk Perkin-Elmer GmbH, D-88647, Überlingen, Germany

Abstract:A fully automated procedure for the determination of ng l?1 amounts of lead has been developed using flow injection (FI) online column preconcentration coupled with electrothermal atomic absorption spectrometry (ETAAS). The proposed FI manifold and its operation make possible the introduction of the total eluate volume into the graphite atomizer, avoiding the necessity for optimization of subsampling the eluate. The interference of other heavy metal ions due to competition for active sites of the sorbent is overcome using a highly selective macrocycle immobilized on silica gel (Pb-02). Lead is adsorbed on a microcolumn (50 μl) packed with Pb-02, and after washing the column with dilute nitric acid, air is introduced to remove all solution from the column and connecting tubing. The sorbed analyte is then eluted quantitatively into the graphite tube atomizer, preheated to 100°C, with 36 μl of ETDA solution (0.035 mol l?1, pH 10.5), propelled by air in order to minimize dispersion. The collection efficiency was 77% and with a sample loading flow rate of 3 ml min?1 and a 60 s preconcentration time, the enhancement factor was 77 and the throughput was 17 samples per hour. The relative standard deviation (n = 10) at the 300 ng l?1 level was 2.7%, and the detection limit (3σ) was 0.4 ng l?1. No interference from heavy metals was observed, but ions of Ba2+, Sr2+ and K+ were found to interfere when the concentration ratios of interferent to lead exceeded values of 2000, 20 000 and 200 000, respectively. Quantitative recovery of lead was achieved from sodium, magnesium, aluminum, lanthanum and heavy metal salt solutions. The high selectivity and sensitivity, combined with extremely low blank values, make the proposed technique particularly attractive for the analysis of high-purity reagents, semiconductors and other high-purity materials. Results are presented for the determination of lead in some high-purity reagents.
Keywords:Air segmentation  Electrothermal atomic absorption spectrometry  Flow injection atomic absorption spectrometry  High-purity reagents  Immobilized macrocycle  Lead determination  On-line microcolumn preconcentration
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号