首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高电荷态ECR离子源引出束流4D 发射度测量仪设计
引用本文:赵阳阳,赵红卫,孙良亭,杨尧,王云,曹云.高电荷态ECR离子源引出束流4D 发射度测量仪设计[J].原子核物理评论,2013,30(4):413-419.
作者姓名:赵阳阳  赵红卫  孙良亭  杨尧  王云  曹云
作者单位:中国科学院近代物理研究所,甘肃兰州730000;
摘    要:为了进一步探究高电荷态电子回旋共振(ECR) 离子源引出束流品质和横向相空间耦合情况,根据中国科学院近代物理研究所高电荷态离子源引出束流发射度测量需求,针对束流流强为1 eμA~1 emA,能量范围为10~35 keV/q 的直流或脉冲高电荷态重离子束,设计了一台实时四维Pepper-pot 发射度测量仪。该Pepper-pot 型发射度测量仪具有响应时间快和工作范围宽等特点。针对强流重离子束诊断的特点,在结构与材料选择上做了设计与优化,并对获得图像的处理方法提出了具体的解决办法。For the purpose of on-line beam quality diagnostics and transverse emittance coupling investigation of the ion beams delivered by an Electron Cyclotron Resonance (ECR) ion source, a real-time 4D Pepper Pot type emittance scanner is under development at IMP(Institute of Moden Physics, Chinese Academy of Sciences). The high charge state ECR ion source at IMP could produce CW or pulsed heavy ion beam intensities in the range of 1 eμA~1 emA with the kinetic energy of 10~35 keV/q, which needs the design of the Pepper Pot scanner to be optimized accordingly. The Pepper Pot scanner has many features, such as very short response time and wide dynamic working range that the device could be applied. Since intense heavy ion beam bombardment is expected for this device, the structure and the material selection for the device is specially considered during the design, and a feasible solution to analyze the pictures acquired after the data acquisition is also made.

关 键 词:高电荷态离子    ECR  离子源    4D  发射度    Pepper-pot  型发射度测量仪    数字图像
收稿时间:1900-01-01

Design of a 4D Emittance Measurement Device for High Charge State ECR Ion Sources
Institution:Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;University of Chinese Academy of Sciences, Beijing 100049, China;
Abstract:For the purpose of on-line beam quality diagnostics and transverse emittance coupling investigation of the ion beams delivered by an Electron Cyclotron Resonance (ECR) ion source, a real-time 4D Pepper Pot type emittance scanner is under development at IMP(Institute of Moden Physics, Chinese Academy of Sciences). The high charge state ECR ion source at IMP could produce CW or pulsed heavy ion beam intensities in the range of 1 eμA~1 emA with the kinetic energy of 10~35 keV/q, which needs the design of the Pepper Pot scanner to be optimized accordingly. The Pepper Pot scanner has many features, such as very short response time and wide dynamic working range that the device could be applied. Since intense heavy ion beam bombardment is expected for this device, the structure and the material selection for the device is specially considered during the design, and a feasible solution to analyze the pictures acquired after the data acquisition is also made.
Keywords:
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号