首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A setup for active neutron analysis of the fissile material content in fuel assemblies of nuclear reactors
Authors:A V Bushuev  A F Kozhin  T B Aleeva  V N Zubarev  E V Petrova  V E Smirnov
Institution:1.National Research Nuclear University MEPhI,Moscow,Russia
Abstract:An active neutron method for measuring the residual mass of 235U in spent fuel assemblies (FAs) of the IRT MEPhI research reactor is presented. The special measuring stand design and uniform irradiation of the fuel with neutrons along the entire length of the active part of the FA provide high accuracy of determination of the residual 235U content. AmLi neutron sources yield a higher effect/background ratio than other types of sources and do not induce the fission of 238U. The proposed method of transfer of the isotope source in accordance with a given algorithm may be used in experiments where the studied object needs to be irradiated with a uniform fluence.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏