首页 | 本学科首页   官方微博 | 高级检索  
     


Neutron collimator design of neutron radiography basedon the BNCT facility
Authors:YANG Xiao-Peng  YU Bo-Xiang  LI Yi-Guo  PENG Dan  LU Jin  ZHANG Gao-Long  ZHAO Hang  ZHANG Ai-Wu  LI Chun-Yang  LIU Wan-Jin  HU Tao
Abstract:For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0·106 n/cm2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.
Keywords:
点击此处可从《中国物理C(英文版)》浏览原始摘要信息
点击此处可从《中国物理C(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏