首页 | 本学科首页   官方微博 | 高级检索  
     检索      


HEAT TRANSFER AND PRESSURE DROP FROM LOUVERED SURFACES IN AUTOMOTIVE HEAT EXCHANGERS
Authors:Bengt Sunden  Jerker Svantesson
Institution:Department of Thermo-and Fluid Dynamics , Chalmers University of Technology , Gbteborg, 41296, Sweden
Abstract:An investigation of heat transfer and pressure drop from some louvered surfaces is presented. The test rig and the measuring as well as the data evaluating procedures are described. The measured data are transferred and presented in a nondimenswnal form. The heal transfer data are provided mainly as Stanton numbers versus Reynolds number, and the pressure drop is given as Darcy friction factors versus Reynolds number. For comparing the performance of the various louvered surfaces, the flow area goodness factors and the so-called volume goodness factors are presented. All the louvered surfaces have been found to be more efficient than the corresponding smooth surface. The standard multilouvered fin surfaces were found to be most efficient, but one of the new surfaces also performed very well.
Keywords:late ultra-fast  early ultra-fast  atomized spray  hot plate
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号