Experimental and numerical study of mixed convection with flow reversal in coaxial double-duct heat exchangers
Authors:Thierry Mar  , Nicolas Galanis, Ionut Voicu, Jacques Miriel,Ousmane Sow
Affiliation:

aLaboratoire de Génie Civil et de Génie Mécanique (LGCGM), INSA de Rennes, IUT Saint Malo, 35043 Rennes, France

bFaculté de génie, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 2R1

cLaboratoire d’Énergie Appliquée, École supérieure Polytechnique, Dakar, Senegal

Abstract:Velocity vectors in a vertical coaxial double-duct heat exchanger for parallel ascending flow of water under conditions of laminar mixed convection have been determined experimentally using the particle image velocimetry technique. The measured velocity distributions for large annular flow rates, resulting in an essentially isothermal environment for the stream in the inner tube, are in very good agreement with corresponding numerical predictions. For flow rates of the same order of magnitude in the inner tube and the annulus, and corresponding temperature differences of about 20 °C, experimental observations show that flow reversal occurs simultaneously in both streams over large axial distances for both heating and cooling of the flow in the inner tube.
Keywords:Velocity measurements   Mixed convection   PIV   Heat exchangers