首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal analysis and water-cooling design of the CSNS MEBT 324 MHz buncher cavity
Authors:LIU Hua-Chang  OUYANG Hua-Fu
Abstract:At least two bunchers are needed in the 3 MeV H- Medium Energy Beam Transport(MEBT)line located between RFQ and DTL for the CSNS(China Spallation Neutron Source).A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity,higher impedance and lower risk of multipacting.By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH,the thermal and structural analyses have been carried out,the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented,the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.
Keywords:buncher cavity  thermal and structural analysis  water-cooling frequency shift  cavity  MEBT  design  analysis  channel  position  the optimum  tuning  method  cooling  water temperature  resonance  structural analyses  process  determine  frequency shift  structural distortion  thermal  making  results
本文献已被 万方数据 等数据库收录!
点击此处可从《中国物理C(英文版)》浏览原始摘要信息
点击此处可从《中国物理C(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏