Abstract: | Spatial-carrier phase-shifting method (SCPM) retrieves the phase distribution from carrier interferograms by assuming that the phases of the processed pixel and its adjacent pixels are uniform,which introduces considerable theoretical error. A new method is presented in this paper to improve the SCPM accuracy: (1) A quadric curve is used to describe the phase distribution of the adjacent pixels; (2) The linear and quadric terms of the phase are considered as phase shifter errors; (3)Suitable phase shifting algorithms insensitive to these errors are selected. Two "5-step" algorithms are used and their properties are analyzed. An example ofphase retrieving by SCPM is given and the result shows that SCPM has high theoretical accuracy. With the potential high accuracy, ability of measuring dynamic phase andcomputational simplicity, SCPM will become a much more useful phase measurement method. |