首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validation of a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of N,N-dimethylacetamide and N-monomethylacetamide in pediatric plasma
Authors:Sebastian P A Rosser  Andrew J McLachlan  Georg Hempel  Jason Chung  Peter J Shaw  Steven J Keogh  Christa E Nath
Institution:1. The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia;2. Sydney Pharmacy School, Faculty of Medicine and Health, University of Sydney, Sydney, Australia;3. Institute for Pharmaceutical and Medicinal Chemistry and Clinical Pharmacy, University of Münster, Sydney, Germany;4. The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia

Department of Biochemistry, The Children's Hospital at Westmead, Sydney, Australia;5. The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia

Cancer Centre for Children, The Children's Hospital at Westmead, Sydney, Australia;6. Cancer Centre for Children, The Children's Hospital at Westmead, Sydney, Australia;7. Department of Biochemistry, The Children's Hospital at Westmead, Sydney, Australia

Abstract:N,N–dimethylacetamide is an excipient used in intravenous busulfan formulations, a drug used in hematopoietic stem cell transplantation conditioning. The aim of this study was to develop and validate a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of N,N-dimethylacetamide, and its metabolite N-monomethylacetamide in plasma from children receiving busulfan. A 4 μl aliquot of patient plasma was extracted using 196 μl 50% methanol solution and quantified against calibrators prepared in the extraction solvent given negligible matrix effects across three concentrations. 9H2]-N,N-dimethylacetamide was used as an internal standard. Separation of N,N-dimethylacetamide and N-monomethylacetamide was achieved using a Kinetex EVO C18 stationary phase (100 mm × 2.1 mm × 2.6 μm) running an isocratic mobile phase of 30% methanol containing 0.1% formic acid at a flow of 0.2 ml/min over 3.0 min. The injection volume was 1 μl. Calibration curves for N,N-dimethylacetamide and N-monomethylacetamide were linear up to 1200 and 200 μg/L, respectively, with a lower limit of quantification 1 μg/L for both analytes. Calibrator accuracy and precision were within ± 10% of the test parameters across four concentration levels. Analytes were stable over 14 days at three different storage conditions. This method was successfully applied to measure N,N-dimethylacetamide and N-monomethylacetamide concentrations in a total of 1265 plasma samples from 77 children.
Keywords:liquid chromatography-tandem mass spectrometry  method validation  N  N-dimethylacetamide  N-monomethylacetamide  pharmacokinetics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号