首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Microinjection Molded Biopolymeric Airway Stent with Antibacterial and Anti-Hyperplastic Properties
Authors:Jiahui Dong  Yahua Li  Xiaofeng Wang  Yajing Liu  Kewei Ren  Xuedi Liu  Han Zhang  Zongming Li  Xinwei Han  Hiroshi Uyama  Qian Li
Institution:1. School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450001 China

School of Mechanics and Safety Engineering, National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou, 450001 China

Department of Applied Chemistry, Osaka University, Suita, Osaka, 565-0871 Japan;2. Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052 China;3. School of Mechanics and Safety Engineering, National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou, 450001 China;4. Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052 China

Engineering Technology Research Center for Minimally Invasive Interventional Tumors of Henan Province, Zhengzhou, 450052 China;5. School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450001 China

School of Mechanics and Safety Engineering, National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou, 450001 China;6. Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052 China

Interventional Institute of Zhengzhou University, Zhengzhou, 450052 China;7. Department of Applied Chemistry, Osaka University, Suita, Osaka, 565-0871 Japan;8. School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450001 China

Abstract:Central airway stenosis is a condition that the diameter of the trachea or main bronchus shrinkage is caused by external compression or internal tissue hyperplasia, which can cause difficulty breathing, asphyxia, and even death. Airway stenting is an easy way to restore the patency of the central airway, but airway stents commonly used in clinical practice can lead to complications such as mucus plugging, bacterial infection, and granulation tissue hyperplasia. Moreover, the non-degradable characteristic makes it requires a second operation to remove, which has the potential to cause tissue damage. In this study, a biodegradable airway stent is fabricated by microinjection molding using the bioelastomer of poly (L-lactide-co-ε-caprolactone) as the matrix material. The airway stent has excellent mechanical properties and an appropriate degradation rate. The hydrophilic surface of the airway stent can inhibit mucus plugging. The loading of silver nanoparticles and cisplatin endows the stent with antibacterial and anti-hyperplastic functions. In vitro and in vivo experiments demonstrate that this study provides an antibacterial and anti-hyperplastic biodegradable airway stent with elastic properties to avoid secondary removal operation and reduce complications associated with mucus plugging, bacterial infection, and granulation tissue hyperplasia.
Keywords:airway stents  antibacterial  anti-hyperplasia  biodegradable  poly (L-lactide-co-ε-caprolactone)
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号