首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Differential-pulse polarography (DPP) determination of betamethasone valerate in dosage form
Authors:Email author" target="_blank">J-E?BelgaiedEmail author
Institution:Institut National des Sciences Appliquées et de Technologies, B.P. 676, 1080, Tunis Cedex, Tunisia. Jamel.Belgaied@insat.rnu.tn
Abstract:The electrochemical reduction of betamethasone valerate (BV) in a pharmaceutical formulation containing neomycin has been carried out in Britton-Robinson buffer (BRB) (0.04 mol L(-1)) by differential-pulse polarography (DPP). BV exhibits a well-defined irreversible reduction peak at -1.03 V/ref. The influence of pH on the reduction of BV was studied in Britton-Robinson buffer (pH range 1.7-10). A method for the analysis of BV in BRB (0.04 mol L(-1)), which allows quantification over the range 3.9x10(-6)-1.1x10(-4) mol L(-1), was proposed and successfully applied to the determination of BV in tablets with mean recovery and relative standard deviation of 100.81% and 0.45%, respectively.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!