首页 | 本学科首页   官方微博 | 高级检索  
     


Non-monotonic dose dependence of the Ge- and Ti-centres in quartz
Affiliation:Forschungsstelle Archäometrie der Heidelberger Akademie der Wissenschaften, Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany
Abstract:The dose response of the Ge- and Ti-centres in quartz is studied over a large dose range. After an initial signal increase in the low dose range, both defects show a pronounced decrease in signal intensities for high doses. The model by Euler and Kahan [1987. Radiation effects and anelastic loss in germanium-doped quartz. Phys. Rev. B 35 (9), 4351–4359], in which the signal drop is explained by an enhanced trapping of holes at the electron trapping site, is critically discussed. A generalization of the model is then developed, following similar considerations by Lawless et al. [2005. A model for non-monotonic dose dependence of thermoluminescence (TL). J. Phys. Condens. Matter 17, 737–753], who explained a signal drop in TL by an enhanced recombination rate with electrons at the recombination centre. Finally, an alternative model for the signal decay is given, based on the competition between single and double electron capture at the electron trapping site. From the critical discussion of the different models it is concluded that the double electron capture mechanism is the most probable effect for the dose response.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号