Design of a 24 GHz, 25-50 kW Technology Gyrotron Operating at the Second Harmonic |
| |
Authors: | P-K Liu E Borie and M V Kartikeyan |
| |
Institution: | (1) Institut für Hochleistungsimpuls and Mikrowellentechnik (IHM), Forschungszentrum Karlsruhe, Association Euratom-FZK, Hermann-von-Helmholtzplatz 1, D-76344 Eggenstein-Leopoldshafen, Germany;(2) Central Electronics Engineering Research Institute, Industrial Tubes Group, Microwave Tubes Area, Pilani, 333031, India |
| |
Abstract: | The preliminary design of a moderate (25-50 kW) gyrotron operating at the ISM (industrial, scientific, medical) frequency of 24.1 GHz is presented. Operation at the second harmonic is considered so that one can obtain radiation at the given frequency with only half the magnetic field required. |
| |
Keywords: | technology gyrotron second harmonic |
本文献已被 SpringerLink 等数据库收录! |
|