首页 | 本学科首页   官方微博 | 高级检索  
     


Reduced Graphene Oxide/Carbon Nanotube/Gold Nanoparticles Nanocomposite Functionalized Screen‐Printed Electrode for Sensitive Electrochemical Detection of Endocrine Disruptor Bisphenol A
Authors:Yi‐Cheng Wang  Dilek Cokeliler  Sundaram Gunasekaran
Affiliation:1. Department of Biological Systems Engineering, University of Wisconsin‐Madison, 460 Henry Mall, Madison, WI 53705, USA;2. Department of Biomedical Engineering, Baskent University, 06810, Baglica Campus, Ankara, Turkey
Abstract:We fabricated a highly sensitive electrochemical sensor for the determination of bisphenol A (BPA) in aqueous solution by using reduced graphene oxide (RGO), carbon nanotubes (CNT), and gold nanoparticles (AuNPs)‐modified screen‐printed electrode (SPE). GO/CNT nanocomposite was directly reduced to RGO/CNT on SPE at room temperature. AuNPs were then electrochemically deposited in situ on RGO/CNT‐modified SPE. Under optimized conditions, differential pulse voltammetry (DPV) produced linear current responses for BPA concentrations of 1.45 to 20 and 20 to 1,490 nM, with a calculated detection limit of an ultralow 800 pM. The sensor response was unaffected by the presence of interferents such as phenol, p‐nitrophenol, pyrocatechol, 2,4‐dinitrophenol, and hydroquinone.
Keywords:Environmental monitoring  Food safety  Graphene  Electrodeposition  Electrochemical reduction  Electrochemical sensor
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号