Immunodetection of inactivated Francisella tularensis bacteria by using a quartz crystal microbalance with dissipation monitoring
Authors:K Kleo  D Schäfer  S Klar  D Jacob  R Grunow  F Lisdat
Institution:Biosystems Technology, Technical University of Applied Sciences Wildau, Wildau, Germany. kleo@th-wildau.de
Abstract:Francisella tularensis are very small, gram-negative bacteria which are capable of infecting a number of mammals. As a highly pathogenic species, it is a potential bioterrorism agent. In this work we demonstrate a fast immunological detection system for whole F. tularensis bacteria. The technique is based on a quartz crystal microbalance with dissipation monitoring (QCMD), which uses sensor chips modified by a specific antibody. This antibody is useful as a capture molecule to capture the lipopolysaccharide structure on the surface of the bacterial cell wall. The QCMD technique is combined with a microfluidic system and allows the label-free online detection of the binding of whole bacteria to the sensor surface in a wide dynamic concentration range. A detection limit of about 4 × 10(3) colony-forming units per milliliter can be obtained. Furthermore, a rather short analysis time and a clear discrimination against other bacteria can be achieved. Additionally, we demonstrate two possibilities for specific and significant signal enhancement by using antibody-functionalized gold nanoparticles or an enzymatic precipitation reaction. These additional steps can be seen as further proof of the specificity and validity.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!