首页 | 本学科首页   官方微博 | 高级检索  
     检索      

柱前衍生-反相高效液相色谱法测定2-去氧葡萄糖的含量
引用本文:尤小云,洪碧红,谢全灵,易瑞灶,许瑞安.柱前衍生-反相高效液相色谱法测定2-去氧葡萄糖的含量[J].分析化学,2012,40(5):782-786.
作者姓名:尤小云  洪碧红  谢全灵  易瑞灶  许瑞安
作者单位:1. 华侨大学分子药物学研究所,泉州362021;国家海洋局第三海洋研究所,厦门361005
2. 国家海洋局第三海洋研究所,厦门361005;厦门大学化学化工学院材料科学与工程系,厦门361005
3. 国家海洋局第三海洋研究所,厦门,361005
4. 华侨大学分子药物学研究所,泉州362021;分子药物教育部工程研究中心,厦门市海洋与基因工程重点实验室,厦门361021
基金项目:海洋公益性行业科研专项经费基金,福建省科技重大专项经费基金,厦门 市海洋与渔业局科技计划项目经费基金
摘    要:采用对氨基苯甲酸乙酯为衍生化试剂,建立柱前衍生化反相高效液相色谱法(RP-HPLC)测定2-去氧葡萄糖的含量.结果表明,最适的衍生化条件为反应温度85℃,反应时间1.5 h,衍生化试剂(ABEE)和单糖(2-DG/Glu)的摩尔比为25∶1;色谱条件为色谱柱Hypersil ODS2 (250 mm×4.6 mm,5μm),流动相为0.02%TFA-乙腈(80∶20,V/V),流速1.0 mL/min,波长307 nm.本方法在1~700 mg/L浓度范围内与峰面积呈良好的线性关系(r-0.9999);定量限(S/N-10)及检出限(S/N-3)分别为450和100 μg/L;平均加标回收率为101.7%;RSD为0.7%;日内及日间精密度均小于0.7%.表明本方法灵敏度高,测定结果准确,重复性好,可用于2-去氧葡萄糖样品的准确定量分析.

关 键 词:2-去氧葡萄糖  柱前衍生  反相高效液相色谱法  对氨基苯甲酸乙酯

Detection of 2-Deoxyglucose by Pre-column Derivation Reversed Phase High Performance Liquid Chromatography
YOU Xiao-Yun , HONG Bi-Hong , XIE Quan-Ling , YI Rui-Zao , XU Rui-An.Detection of 2-Deoxyglucose by Pre-column Derivation Reversed Phase High Performance Liquid Chromatography[J].Chinese Journal of Analytical Chemistry,2012,40(5):782-786.
Authors:YOU Xiao-Yun  HONG Bi-Hong  XIE Quan-Ling  YI Rui-Zao  XU Rui-An
Institution:1,3 1(Institute of Molecular Medicine,Huaqiao University,Quanzhou 362021,China) 2(The Third Institute of Oceanography State Oceanic Administration,Xiamen 361005,China) 3(Xiamen Key Lab of Marine & Gene Engineering Drugs & Engineering Research Center of Molecular Medicine, Ministry of Education,Xiamen 361021,China) 4(Department of Materials Science and Technology,College of Chemistry and Chemical Engineering, Xiamen University,Xiamen 361005,China)
Abstract:A method was developed for the determination of 2-deoxyglucose(2-DG)by reversed phase high performance liquid chromatography(RP-HPLC) after pre-column derivated with p-aminobenzoic ethyl ester(ABEE).The results showed that the optimum derivation conditions were as follows: reaction temperature was 85 ℃,reaction time was 1.5 h and molar ratio of derivative reagent(ABEE) to monosaccharide(2-DG/Glu) was 25∶1.The derivative was analyzed on a Hypersil ODS 2(250 mm×4.6 mm,5 μ) column with a mixture of acetonitrile to 0.02% trifluoroacetic acid(TFA)(2∶80,V/V) as the mobile phase,at the flow rate of 1.0 mL/min and the detection wavelength at 307 nm.This method has a good linearity at the concentration from 1 mg/L to 700 mg/L(r=0.9999).The limit of detection was 100 μg/L while the quantitative limit was 450 μg/L.The average recovery of 2-DG was 101.7% and the relative standard deviation(RSD) was 0.7%.The inter-day and intra-day precision were both less than 0.7%,This method is of high sensitivity,precision and repetition,indicating that it is suitable for precise quantitative determination of 2-DG.
Keywords:2-Deoxyglucose  Pre-column derivatization  Reversed phase high performance liquid chromatography  p-Aminobenzoic ethyl ester
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号