首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Dynamic pressure based prediction of spray cooling heat transfer coefficients
Authors:Bahman Abbasi  Jungho Kim  Andre Marshall
Institution:1. Dept. of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA;2. Dept. of Fire Protection Engineering, University of Maryland, College Park, MD 20742, USA
Abstract:An important goal of spray cooling research is the ability to predict local heat transfer from the spray hydrodynamics. It is postulated that the local normal pressure exerted by the spray onto the heated surface can be used to obtain the local heat transfer coefficient. This hypothesis was tested using data obtained from hollow cone, full cone, and linear sprays at four nozzle pressures and three stand-off distances. A correlation between the pressure and heat transfer coefficient was determined from the data, then used to “predict” the heat transfer coefficient to verify the accuracy of the correlation. The area averaged heat transfer coefficient could be predicted within 25%, indicating that pressure can be used to predict the local heat transfer coefficient in the single-phase regime.
Keywords:Spray cooling  Heat transfer  Single-phase  Correlation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号