首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Drop size spectra in sprays from pressure-swirl atomizers
Authors:Andreas Tratnig  Günter Brenn
Institution:Institute of Fluid Mechanics and Heat Transfer, Graz University of Technology, Inffeldgasse 25/F, 8010 Graz, Austria
Abstract:A study on the characterization of sprays from Newtonian liquids produced by pressure-swirl atomizers is presented. The global drop size spectra of the sprays are measured with phase-Doppler anemometry, and global mean drop sizes are derived as moments of the spectra for varying atomizer geometry, liquid flow rate, and physical properties of the liquids. Dimensional analysis provides a correlation for the non-dimensional global Sauter mean diameter. A relationship between the global Sauter mean drop size and the global drop size RMS is established. A method is developed for predicting the global drop size spectra in the sprays, using easily accessible experimental input parameters. The basis for the function defining the spectrum is a gamma distribution, which is known from the literature as physically relevant for ligament-mediated sprays.
Keywords:Conical sheet atomization  Sauter mean drop size  Drop size spectrum  Gamma distribution
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏