Design of the readout electronics for the DAMPE Silicon Tracker detector |
| |
Authors: | Fei Zhang Wen-Xi Peng Ke Gong Di Wu Yi-Fan Dong Rui Qiao Rui-Rui Fan Jin-Zhou Wang Huan-Yu Wang Xin Wu Daniel La Philipp Azzarello Valentina Gallo Giovanni Ambrosi Andrea Nardinocchi |
| |
Affiliation: | 1. Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China2. Dé3. Istituto Nazionale di Fisica Nucleare Sezione di Perugia, Perugia 06100, Italy4. Istituto Nazionale di Fisica Nucleare Sezione di Perugia, Perugia 06100, Italy5. Universitaà |
| |
Abstract: | The Silicon Tracker (STK) is one of the detectors of the DAMPE satellite used to measure the incidence direction of high energy cosmic rays. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73728 readout channels. It is a great challenge to read out the channels and process the huge volume of data in the harsh environment of space. 1152 Application Specific Integrated Circuits (ASIC) and 384 ADCs are used to read out the detector channels. 192 Tracker Front-end Hybrid (TFH) modules and 8 identical Tracker Readout Board (TRB) modules are designed to control and digitalize the front signals. In this paper, the design of the readout electronics for the STK and its performance are presented in detail. |
| |
Keywords: | DAMPE readout electronics silicon strip detector VA140 |
|
| 点击此处可从《中国物理C(英文版)》浏览原始摘要信息 |
|