Photoacoustic monitoring of the mass removed in pulsed laser ablation |
| |
Authors: | Yue Cai N.H. Cheung |
| |
Affiliation: | a Department of Physics, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China |
| |
Abstract: | The mass Δm removed per pulse in laser ablation was shown to correlate with the acoustic signal A and the beam diameter ?. The functional forms of Δm(A, ?) were deduced for aluminum and polyvinyl chloride, for fluence ranging from 1.5 through 88 J cm− 2. Δm so computed agreed with empirical values within experimental error. For samples whose mass is sensitive to environmental factors, off-line measurement of Δm was shown to be unreliable and real-time measurements such as acoustic monitoring became essential. |
| |
Keywords: | Pulsed laser ablation Photoacoustic signal Mass removed |
本文献已被 ScienceDirect 等数据库收录! |
|