首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Ca-P Conversion Coating on AZ60 Magnesium Alloy for Biomedical Application
Authors:CHENG Zhongji  ;LIAN Jianshe HU Xiaoli YANG Xiaohong LI Guangyu
Institution:Key Laboratory of Automobile Materials, Ministry of Education, College of Materials Science and Engineering, Jilin University, Changchun 130022, P. R. China
Abstract:To improve the anti-corrosion behaviors of magnesium alloy in the inner environment of human body, a bioactive Ca-P coating was deposited on the AZ60 magnesium alloy by a novel simple method. The morphologies of the Ca-P coatings formed under different treatment time were studied by scanning electron microscopy(SEM). The corrosion behaviors of Ca-P coating were investigated by electrochemical polarization test and electrochemical impedance spectroscopy in both 3%(mass fraction) NaCl solution and simulated body fluid(SBF). Immersion test in SBF was performed to evaluate the corrosion rate of Ca-P coated magnesium alloy. X-Ray diffraction(XRD) analysis result shows that the coating mentioned above mainly consists of dicalcium phosphate dehydrate(CaHPO4·2H2O, DCPD) and β-tricalcium phosphate dehydrateβ-TCP, Ca3(PO4)2], which exhibits good corrosion resistance. After magnesium alloy was immersed in 1 mol/L NaOH solution at 80℃ for 2 h, hydroxyapatite Ca10(PO4)6(OH)2, HA] appeared on the magnesium alloy substrate, which can further decrease the corrosion rate of AZ60 magnesium alloy in SBF.
Keywords:Ca-P coating  Deposited method  Magnesium alloy  Corrosion rate  Simulated body fluid(SBF)
本文献已被 维普 等数据库收录!
点击此处可从《高等学校化学研究》浏览原始摘要信息