首页 | 本学科首页   官方微博 | 高级检索  
     检索      


HLS bunch current measurement system
Authors:Yang  YongLiang  Ma  TianJi  Sun  BaoGen  Lu  Ping  Wang  JiGang  Zou  JunYing  Tang  LeiLei
Institution:1.National Synchrotron Radiation Laboratory & School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029, China
;
Abstract:

Bunch current is an important parameter for studying the injection fill-pattern in the storage ring and the instability threshold of the bunch, and the bunch current monitor also is an indispensable tool for the top-up injection. A bunch current measurement (BCM) system has been developed to meet the needs of the upgrade project of Hefei Light Source (HLS). This paper presents the layout of the BCM system. The system based on a high-speed digital oscilloscope can be used to measure the bunch current and synchronous phase shift. To obtain the absolute value of bunch-by-bunch current, the calibration coefficient is measured and analyzed. Error analysis shows that the RMS of bunch current is less than 0.01 mA when bunch current is about 5 mA, which can meet project requirement.

Keywords:
本文献已被 SpringerLink 等数据库收录!