杂散光对分光光度计的影响
引用本文:吕良,韩霜,管善国.杂散光对分光光度计的影响[J].化学分析计量,2011,20(2):63-64.
作者姓名:吕良  韩霜  管善国
作者单位:济南市计量检定所,济南,250002
摘    要:介绍了杂散光产生的原因以及杂散光的测试方法,并指出杂散光对光学系统的一些影响和危害,提出了减小及消除杂散光的措施.

关 键 词:分光光度计  杂散光  吸光度  朗伯-比耳定律

IMPACT OF STRAY LIGHT ON THE SPECTROPHOTOMETER
Lü Liang,Han Shuang,Guan Shanguo.IMPACT OF STRAY LIGHT ON THE SPECTROPHOTOMETER[J].Chemical Analysis And Meterage,2011,20(2):63-64.
Authors:Lü Liang  Han Shuang  Guan Shanguo
Institution:(Jinan Institute of Metrological Verification, Jinan 250002, China)
Abstract:Causes and test method of stray light were introuduced. Effect and harm of stray light to optical system were pointed out. The measures to reduce and eliminate stray light were put forward.
Keywords:spectrophotometer  stray light  absorbance  Lambert - Beer law