首页 | 本学科首页   官方微博 | 高级检索  
     


On the dependence of the laser-induced incandescence (LII) signal on soot volume fraction for variations in particle size
Authors:H. Bladh  J. Johnsson  P.-E. Bengtsson
Affiliation:(1) Division of Combustion Physics, Lund Institute of Technology, P.O. Box 118, 22100 Lund, Sweden
Abstract:“The laser-induced incandescence (LII) signal is proportional to soot volume fraction” is an often used statement in scientific papers, and it has – within experimental uncertainties – been validated in comparisons with other diagnostic techniques in several investigations. In 1984 it was shown theoretically in a paper by Melton that there is a deviation from this statement in that the presence of larger particles leads to some overestimation of soot volume fractions. In the present paper we present a detailed theoretical investigation of how the soot particle size influences the relationship between LII signal and soot volume fraction for different experimental conditions. Several parameters have been varied; detection wavelength, time and delay of detection gate, ambient gas temperature and pressure, laser fluence, level of aggregation and spatial profile. Based on these results we are able, firstly, to understand how experimental conditions should be chosen in order to minimize the errors introduced when assuming a linear dependence between the signal and volume fraction and secondly, to obtain knowledge on how to use this information to obtain more accurate soot volume fraction data if the particle size is known. PACS 42.62.-b; 44.40.+a; 61.46.Df; 78.70.-g; 65.80.+n
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号