Development of quality assessment method for optically active food flavor chemicals |
| |
Authors: | Saito Koichi Hosono Kouhei Kitazawa Nariko Iwasaki Yusuke Ito Rie Nakazawa Hiroyuki |
| |
Affiliation: | Hoshi University, Faculty of Pharmaceutical Sciences, Department of Analytical Chemistry, 2-4-41 Ebara, Shinagawa-ku, Tokyo 142-8501. k-saito@hoshi.ac.jp |
| |
Abstract: | A quality assessment method for commercially available, optically active flavor compounds, namely, menthol, menthyl acetate, borneol, perillaldehyde, and 1,8-cineol, was developed. A gas chromatograph equipped with a flame ionization detector and a DB-5ms capillary column was used for the chemical purity test. A GC/MS with a beta-DEX cyclodextrin column was used for the optical purity test, by which the enantiomeric separation of each flavor compound was achieved. Enantiomeric excess was calculated as an expression of optical purity. Of the 25 standard samples subjected to the chemical purity test, six were found to have lower purity than the data provided by the manufacturers. When the same samples were subjected to the optical purity test, 11 were found to have lower purity than that indicated on the reagent labels. These results suggest that there is a need to conduct an optical purity test, in addition to a chemical purity test, for the quality assessment of flavor standards. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|