Mitigation effects of radon decay products by air cleaner |
| |
Authors: | Kazuki Iwaoka Shinji Tokonami Tetsuo Ishikawa Hidenori Yonehara |
| |
Affiliation: | 1. Research Center for Radiation Protection, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba, 263-8555, Japan 2. Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564, Japan
|
| |
Abstract: | One of the most effective methods for reducing exposure is the use of air cleaners. In this study, a dose mitigation of a commonly-used Japanese air cleaner under conditions in which aerosols are continuously supplied was investigated. Although the values of the EERC during an operation of air cleaner decreased, values of the f p increased with the use of air cleaner. An effective dose was calculated on the basis of our experimental results, resulting in the dose mitigation of about 40 % by the air cleaner. Air cleaners can be regarded as an effective tool for the dose mitigation under with conditions in which aerosols are continuously supplied. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|