首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of novel amylose and cellulose-based chiral stationary phases for the stereoisomer separation of flavanones by means of nano-liquid chromatography
Authors:Kahina Si-Ahmed  Zeineb Aturki  Bezhan Chankvetadze  Salvatore Fanali
Institution:1. Laboratoire d’Analyse Organique Fonctionelle, Faculté de Chimie, USTHB. B.P. 32, El Alia Bab Ezzouar 16111, Alger, Algeria;2. Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Area della Ricerca di Roma 1, Monterotondo, Rome, Italy;3. Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Tbilisi, Georgia
Abstract:Three polysaccharide-based chiral stationary phases, Sepapak® 1, Sepapak® 2 and Sepapak® 3 have been evaluated in the present work for the stereoisomer separation of a group of 12 flavonoids including flavanones (flavanone, 4′-methoxyflavanone, 6-methoxyflavanone, 7-methoxyflavanone, 2′-hydroxyflavanone, 4′-hydroxyflavanone, 6-hydroxyflavanone, 7-hydroxyflavanone, hesperetin, naringenin) and flavanone glycosides (hesperidin, naringin) by nano-liquid chromatography (nano-LC). The behaviour of these chiral stationary phases (CSPs) towards the selected compounds was studied in capillary columns (100 μm internal diameter (i.d.)) packed with the above mentioned CSPs using polar organic, reversed and normal elution modes. The influence of nature and composition of the mobile phase in terms of concentration and type of organic modifier, buffer type and water content (reversed phase elution mode) on the enantioresolution (Rs), retention factor (k) and enantioselectivity (α) was evaluated. Sepapak® 3 showed the best chromatographic results in terms of enantioresolution, enantioselectivity and short analysis time, employing a polar organic phase mode. A mixture of methanol/isopropanol (20/80, v/v) as mobile phase enabled the chiral separation of eight flavanones with enantioresolution factor (Rs) in the range 1.15–4.18. The same analytes were also resolved employing reversed and normal phase modes with mixtures of methanol/water and hexane/ethanol at different ratios as mobile phases, respectively. Loss in resolution for some compounds, broaden peaks and longer analysis times were observed with these last two chromatographic elution modes.
Keywords:Flavanoids  Nano-liquid chromatography  Polysaccharide-based chiral stationary phases  Enantiomer separation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号