首页 | 本学科首页   官方微博 | 高级检索  
     检索      

用直读光谱仪测定铝青铜中铝,铁,锰
引用本文:袁金生.用直读光谱仪测定铝青铜中铝,铁,锰[J].光谱实验室,1997,14(4):83-87.
作者姓名:袁金生
作者单位:北京齿轮总厂齿轮研究所!北京市朝阳区大路园2号,100022
摘    要:本文介绍了直读光谱仪直接测定铝青铜中铝,铁,锰三元素的方法,选择和确定了最佳工作条件,通过一套铜合金国家标准样品作出校准曲线,此法快速,准确,简便,分析结果令人满意。

关 键 词:直读光谱仪  铝青铜      

Determination of Al,Fe and Mn in Aluminium Bronze by Direct Reading Spectrometer
YUAN Jinsheng.Determination of Al,Fe and Mn in Aluminium Bronze by Direct Reading Spectrometer[J].Chinese Journal of Spectroscopy Laboratory,1997,14(4):83-87.
Authors:YUAN Jinsheng
Abstract:This paper reports a method of the direCt determination of metals Al,Fe and Mn in Alumindribronze by direct rending spectrometer. Selecting and determining the best work condition, drawingthe Calibtalion curve of three kinds of element in a set of capper alloy sample which meets China national standard. The method is rapid and convenient to determine element in aluminium bronze. Theresults show that the method has good precisha and accuracy.
Keywords:Direct Reading Spectrometer  Aluminium Bronze  Al  Fe  Mn