首页 | 本学科首页   官方微博 | 高级检索  
     检索      

凝固浴温度对纤维素中空纤维膜结构及气体渗透分离性能影响研究
引用本文:毛智明,介兴明,曹义鸣,刘丹丹,刘建辉,周美青,袁权.凝固浴温度对纤维素中空纤维膜结构及气体渗透分离性能影响研究[J].高分子学报,2011(4):395-401.
作者姓名:毛智明  介兴明  曹义鸣  刘丹丹  刘建辉  周美青  袁权
作者单位:毛智明,MAO Zhiming(中国科学院大连化学物理研究所,大连,116023;中国科学院研究生院,北京,100049);介兴明,曹义鸣,刘丹丹,刘建辉,周美青,袁权,JIE Xingming,CAO Yiming,LIU Dandan,LIU Jianhui,ZHOU Meiqing,YUAN Quan(中国科学院大连化学物理研究所,大连,116023)
基金项目:国家自然科学基金,国家重点基础研究发展计划(973计划),国家自然科学重点基金
摘    要:利用新型溶解工艺,在不同的凝固浴温度(0~60℃)下制备了纤维素中空纤维膜,考察了凝固浴温度对纤维素中空纤维膜结晶结构、机械性能和气体渗透分离性能的影响.扫描电镜表征表明凝固浴温度的升高使得纤维素中空纤维膜更加疏松,并且内侧的指状孔变大变多;膜的机械性能随凝固浴温度的升高而变差;XRD谱图显示凝固浴温度对纤维素中空纤维...

关 键 词:纤维素中空纤维膜  凝固浴  气体分离  Knudson扩散  溶解扩散

EFFECT OF COAGULATION BATH TEMPERATURE ON STRUCTURE AND GAS SEPARATION PROPERTIES OF CELLULOSE HOLLOW FIBER MEMBRANES
MAO Zhiming,JIE Xingming,CAO Yiming,LIU Dandan,LIU Jianhui,ZHOU Meiqing,YUAN Quan.EFFECT OF COAGULATION BATH TEMPERATURE ON STRUCTURE AND GAS SEPARATION PROPERTIES OF CELLULOSE HOLLOW FIBER MEMBRANES[J].Acta Polymerica Sinica,2011(4):395-401.
Authors:MAO Zhiming  JIE Xingming  CAO Yiming  LIU Dandan  LIU Jianhui  ZHOU Meiqing  YUAN Quan
Abstract:Cellulose hollow fiber membranes(CHFMs) were prepared by a new dissolving method.The influence of coagulation bath temperature on the morphology and properties such as crystallinity degree,mechanical strength and gas permeation performance of CHFM was systematically investigated.The results showed that with the increase of coagulation bath temperaturet,he morphology of asymmetric cellulose hollow fiber membranes would become much looser,and more large finger-like pores could be found across the section.At the same time,crystallinity degree almost showed no change and mechanical strength became worse obviously.As a result gas permeation performance of dry CHFMs would increase dramatically with the coagulation bath temperature and show obvious "Knudson-diffusion selective " mechanism.While for wet CHFMs,permeation rates for all gases would decrease sharply and interestingly for CHFMs from coagulation bath temperature of 0℃ and 20℃ carbon dioxide became the fastest gas because of the permeation mechanism had changed to "solution selective"in wet CHFMs.While for CHFMs from coagulation bath temperature of 40℃ and 60℃ t,his"solution selective"effect cannot be found because of their much looser structure.
Keywords:Cellulose hollow fibre membrane  Coagulating bath  Gas separation  Knudson-diffusion  Solution-diffusion
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号