首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Die Berechnung des Blasenwachstums beim Verdampfen von Flüssigkeiten an Heizflächen als numerische Lösung der Erhaltungsgleichungen
Authors:Dr -Ing P Burow  Prof Dr -Ing H Beer
Institution:1. Battelle-Institut e.V.-Abt. Thermische Verfahrenstechnik, Am R?merhof 35, D-6000, Frankfurt am Main 90
2. Institut für Technische Thermodynamik, Technische Hochschule Darmstadt, Petersenstr. 30, D-6100, Darmstadt
Abstract:A numerical procedure on the basis of the Marker and Cell-method 1] was developed in order to solve the conservation equations for mass, momentum and energy for the case of bubble growth on a heating surface. This procedure was used to calculate steam bubble growth on a horizontal stainless steel heating surface under saturated pool boiling conditions at a system pressure of 1 bar and different superheatings. The essential results obtained are:
  • -Good agreement was found between calculations and experiments concerning bubble growth rates, bubble shape and temperature field in the liquid surrounding the bubble.
  • -During its growth the bubble penetrates the temperature boundary layer formed in the liquid on the heating surface, simultaneously liquid is displaced aside.
  • -The microlayer evaporation fraction of the total bubble growth increases with growth time from 20 % to 50%.
  • Keywords:
    本文献已被 SpringerLink 等数据库收录!
    设为首页 | 免责声明 | 关于勤云 | 加入收藏