首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Electrochemical Oxidation of Epinephrine and Uric Acid at a Layered Double Hydroxide Film Modified Glassy Carbon Electrode and Its Application
Authors:Fang Ni  Yinling Wang  Dandan Zhang  Feng Gao  Maoguo Li
Institution:Anhui Key Laboratory of Chemo‐Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P.?R. China
Abstract:Increasing attention has been paid to layered double hydroxide (LDH) film modified electrode attributing to its desirable properties for fabrication of electrochemical sensor. In this paper, the Zn‐Al LDH film modified glassy carbon electrode was characterized by electrochemical methods. The enhanced electrocatalytic currents and well‐separated potentials for epinephrine (EP) and uric acid (UA) were observed at the as‐prepared electrode. Under selected condition, the differential pulse voltammetry response of the modified electrode to EP (or UA) shows a linear concentration range of 0.5 μM to 0.3 mM (or 2 μM to 0.4 mM) in the presence of 10.0 μM UA (or 20.0 μM EP). At a signal‐to‐noise ratio of 3, the calculated limits of detection are 0.13 μM and 0.66 μM, respectively. The proposed method has been performed to successfully detect EP and UA in analysis of real samples, such as in EP injection solution and human urine samples.
Keywords:Epinephrine  Uric acid  Layered double hydroxides  Film modified electrode  Electrooxidation  Glassy carbon electrode  Thin films
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号