首页 | 本学科首页   官方微博 | 高级检索  
     检索      


On the Use of Amperometry for Real Time Assessment of Drug‐Release Profile from Therapeutic Nanoparticles
Authors:Ali A Ensafi  Esmaeil Heydari‐Bafrooei  Behzad Rezaei
Institution:1. Department of Chemistry, Isfahan University of Technology, Isfahan 84156‐83111, Iran tel: (98) 311‐3912351;2. fax: (98) 311‐3912350
Abstract:A simple electrochemical method was used to directly assess the drug‐release profile. The method is based on the multiple pulse amperometric measurement of the oxidation and reduction of doxorubicin released from liposome at a MWCNTs‐modified glassy carbon electrode (MWCNT‐GCE). The released doxorubicin was detected at +0.60 and ?0.60 V by two different oxidation and reduction processes, respectively. The third potential pulse (?1.00 V) was applied for the regeneration of MWCNT‐GCE. The main advantage of this method is that there is no need for any operation for the quantitative analysis during the release of the drug from nanoparticles.
Keywords:Drug release  Voltammetry  Doxorubicin  Liposome  Nanoparticles
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号