首页 | 本学科首页   官方微博 | 高级检索  
     


Multiwall Carbon Nanotube‐Ionic Liquid Modified Paste Electrode as an Efficient Sensor for the Determination of Diazepam and Oxazepam in Real Samples
Authors:M. A. Zare  M. Saber Tehrani  S. Waqif Husain  P. Aberoomand Azar
Affiliation:Department of Chemistry, Science and Research Branch, Islamic Azad University, P.O. Box: 1477893855, Tehran, Iran
Abstract:A carbon‐based electrode using multiwall carbon nanotube as a modifier and room temperature ionic liquid as a binder has been applied for the determination of diazepam (DZP) and oxazepam (OZP) in real samples including serum, urine and tablets. Square wave voltammetry as an appropriate electrochemical technique was applied to achieve improved limits of detection and higher sensitivities. The electrochemical studies were investigated under various experimental conditions such as pH, buffer concentration, ionic strength, deposition potential, deposition time and scan rate to achieve higher sensitivities. Linear concentration ranges for DZP and OZP were 0.02–0.76 mg L?1 and 0.05–1.90 mg L?1 with the detection limits of 4.1 µg L?1 and 5.8 µg L?1, respectively. The proposed method was successfully applied for the analysis of commercially available tablets as well as serum and urine samples and satisfactory results were obtained.
Keywords:Diazepam  Oxazepam  Ionic liquid  Multiwall carbon nanotube  Serum
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号