Determination of procaine hydrochloride by ion-pairing flow injection analysis with piezoelectric detection |
| |
Authors: | Z Mo J Luo Xiaohui Long Ziling Xia |
| |
Institution: | Department of Applied Chemistry, Sichuan Union University, Chengdu 610065, PR China, CN College of Chemistry and Chemical Engineering, Chongqing University, Chongqing 630044, PR China, CN
|
| |
Abstract: | A fast and simple method for the determination of procaine hydrochloride by ion-pairing flow injection analysis has been developed. It is based on the formation of an ion-pair with sodium dodecyl phenylsulphonate and piezoelectric detection. The calibration curve was linear between 0.02 and 2.00 mg/mL, with a detection limit of 0.01 mg/mL, a relative standard deviation of 0.3% (10 replicates) and a sampling frequency of 120/h. The proposed method has been satisfactorily applied to the determination of procaine hydrochloride in pharmaceutical preparations. |
| |