Comparison of passive and active sampling methods for the determination of nitrogen dioxide in urban air
Authors:Oddvar Røyset
Institution:Norwegian Institute for Air Research, P.O.Box 100, N-2007 Kjeller, Norway, NO
Abstract:Three different methods for sampling and determination of nitrogen dioxide in urban air are compared: an NO/NOx-monitor and an active (pumped) and a passive sampling method. For the latter two methods, sodium iodide is used as absorbent. For weekly averages the results from the passive sampler are within 10–20% of the results for the two other methods in the concentration range 15–30 μg NO2/m3. The detection limit for the passive sampler is 1 μg NO2/m3 (7 days), the precision is 5% and the accuracy is estimated to 20%. The active iodide method agrees very well with the NO/NOx-monitor. Compared on 24 h basis for a period of 3 months, covering a concentration range of 5–45 μg NO2/m3, the deviation between the two methods is within 5%, and the absorption capacity of the iodide reagent is excellent as the breakthrough is below 1%.