Abstract:A gas-liquid chromatographic method with electron-capture detection using a capillary column with the inlet in the splitless injection mode is reported for the assay of propafenone. A 25 m X 0.31 mm cross-linked, 5% phenylmethylsilicone-coated fused-silica capillary column was employed for all analyses. The present method provides improved selectivity and sensitivity over other existing gas chromatographic and high-performance liquid chromatographic (HPLC) methods. Linearity was observed in the ranges 2.5-50 and 10-100 ng/ml. The coefficient of variation was found to be less than 10% over the concentration ranges studied. Application of the developed method is demonstrated by measuring serum propafenone concentrations over 24 h in a normal healthy volunteer after a single oral dose of propafenone and by measuring trough plasma propafenone concentrations at steady state in patients receiving this new antiarrhythmic drug. Validity of the present method is further demonstrated by comparison of analytical results obtained from measurement of patient samples using a modified published HPLC method.