Simultaneous determination of chromium (III) and chromium (VI) by reversed-phase ion-pair HPLC with chromium-specific detection |
| |
Authors: | J. Lintschinger K. Kalcher W. G?ssler G. K?lbl M. Novic |
| |
Affiliation: | (1) Institut für Analytische Chemie, Karl-Franzens Universität Graz, Universitätsplatz 1, A-8010 Graz, Austria;(2) National Institute of Chemistry, Hajdrihova 19, SLO-61115 Ljubljana, Slovenia |
| |
Abstract: | A method for the simultaneous determination of Cr(III) and Cr(VI) with reversed-phase ion-pair HPLC employing chromium-specific detection by flame atomic absorption spectrometry (FAAS) and inductively-coupled plasma mass spectrometry (ICP-MS) is presented. Experimental parameters of the chromatographic separation, such as concentration of the ion-pairing reagent, pH and polarity of the mobile phase have been optimized for two different ion-pairing reagents, tetrabutylammonium phosphate (TBA) and tetraethylammonium nitrate (TEA). Best chromatographic conditions have been obtained with a polymer-based reversed-phase column (Hamilton PRP1) and mobile phases containing either TBA (1 mmol/l) in methanol-water (60:40, v/v) or TEA (2 mmol/l) in water at a pH between 3 and 4. With FAAS the detection limits (3) have been found to be 24 g/l for Cr(III) and 40 g/l for Cr(VI). A detection limit of 0.3 g/l Cr(3) for both chromium species has been obtained when ICP-MS has been used for detection. The method has been applied to analyze tap- and groundwater and to investigate the behaviour of Cr(III) and Cr(VI) in spiked tap-water, as well as to analyze aqueous extracts of coal fly ash (NIST SRM 1633a) and of an ash from a wood treatment company. |
| |
Keywords: | |