Determination of cocaethylene, cocaine and their metabolites in rat serum microsamples by high-performance liquid chromatography, and its application to pharmacokinetic studies in rodents. |
| |
Authors: | C E Lau |
| |
Institution: | Department of Psychology, Rutgers University, New Brunswick, NJ 08903. |
| |
Abstract: | A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating cocaethylene in rat serum microsamples (50 microliters), a substance formed in vivo when cocaine and ethanol are present concurrently. The separation used a 2 mm I.D. reversed-phase Nova-Pak C18 column with a mobile phase of acetonitrile-phosphate buffer containing an ion-pairing reagent. With an ultraviolet detector operated at 230 nm, a linear response was observed from 0.05 to 2.0 micrograms/ml with a detection limit of 5 ng/ml for cocaethylene, cocaine and norcocaine. The method showed a longer half-life for cocaethylene than for cocaine in rat. |
| |
Keywords: | |
|
|