首页 | 本学科首页   官方微博 | 高级检索  
     

在线固相萃取/高效液相色谱法测定环境水样中的4种痕量邻苯二甲酸酯
引用本文:徐磊, 夏宁. 在线固相萃取/高效液相色谱法测定环境水样中的4种痕量邻苯二甲酸酯[J]. 分析测试学报, 2011, 30(5): 558-561. DOI: 10.3969/j.issn.1004-4957.2011.05.016
作者姓名:徐磊   夏宁
作者单位:1.国土资源部海洋油气资源与环境地质重点实验室;2.青岛海洋地质研究所
摘    要:建立了一种在线固相萃取/高效液相色谱测定水样中4种痕量邻苯二甲酸酯(邻苯二甲酸甲酯、邻苯二甲酸乙酯、邻苯二甲酸丁酯和邻苯二甲酸(2-乙基)己酯)的新方法.样品由外加泵注入一根固相萃取小柱上进行富集,再将富集柱切换至高效液相色谱系统中,将富集在固相萃取小柱的邻苯二甲酸酯洗脱至分析柱进行分析.在线固相萃取柱为IonPac(...

关 键 词:邻苯二甲酸酯  在线固相萃取  高效液相色潜  水样

Determination of Four Trace Phthalates in Water by Online SPE Coupled with High Performance Liquid Chromatography
XU Lei,XIA Ning. Determination of Four Trace Phthalates in Water by Online SPE Coupled with High Performance Liquid Chromatography[J]. Journal of Instrumental Analysis, 2011, 30(5): 558-561. DOI: 10.3969/j.issn.1004-4957.2011.05.016
Authors:XU Lei  XIA Ning
Affiliation:1,2 (1.Key Laboratory of Marine Hydrocarbon Resources and Environmental Geology,Ministry of Land and Resources, Qingdao 266071,China;2.Qingdao Institute of Marine Geology,Qingdao 266071,China)
Abstract:A method for the simultaneous determination of four trace phthalates(PAEs),e.g.dimethyl phthalate,diethyl phthalate,dibutyl phthalate and bis(2-ethylhexyl) phthalate,in water samples was established using high performance liquid chromatography with the function of online column enrichment.After injected with an assistant pump and concentrated at the solid phase extraction cartridge,the PAEs were back-flushed to the analytical column by a six-port valve switching for detection with mobile phase.The online SPE cartridge was IonPac NG1(10 μm×4.0 mm×35 mm) and the LC column was Acclaim 120 C18(5 μm×4.6 mm×150 mm).The quantitation analysis of four phthalates were achieved by UV detection at 224 nm with 15 mL sample load volume.The linear ranges of four PAEs were in the range of 1-100 μg/L with correlation coefficients(r2) not less than 0.999 8.The method detection limits(S/N=3) of four PAEs were between 0.10 μg/L and 0.25 μg/L.The relative standard deviations(RSDs) of five injections of 10 μg/L working solution were less than 2%.The spiked recoveries at two matrix spiked concentrations were in the range of 88%-107%.The results showed that the developed method was sensitive and accurate,and was suitable for the analysis of trace PAEs in water sample.
Keywords:phthalate  online solid phase extraction  high performance liquid chromatography  water sample
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《分析测试学报》浏览原始摘要信息
点击此处可从《分析测试学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号