首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A screen-printed carbon electrode modified with gold nanoparticles,poly(3,4-ethylenedioxythiophene), poly(styrene sulfonate) and a molecular imprint for voltammetric determination of nitrofurantoin
Authors:Email authorEmail author  Peerada?Yingyuad  Pongthep?Prajongtat  Laemthong?Chuenchom  Chakrit?Sriprachuabwong  Adisorn?Tuantranont  I-Ming?Tang
Institution:1.Department of Materials Science, Faculty of Science,Kasetsart University,Bangkok,Thailand;2.Specialized Center of Rubber and Polymer Materials for Agriculture and Industry (RPM), Faculty of Science,Kasetsart University,Bangkok,Thailand;3.Department of Chemistry, Faculty of Science,Kasetsart University,Bangkok,Thailand;4.Department of Chemistry, Faculty of Science,Prince of Songkla University,Songkla,Thailand;5.National Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA),Pathumthani,Thailand;6.Computational and Applied Science for Smart Innovation Cluster (CLASSIC), Faculty of Science,King Mongkut’s University of Technology,Bangkok,Thailand
Abstract:A molecularly imprinted polymer (MIP) and a nanocomposite prepared from gold nanoparticles (AuNP) and poly(3,4-ethylenedioxythiophene)/poly(styrene sulfonate) (PEDOT:PSS) were deposited on a screen-printed carbon electrode (SPCE). The nanocomposite was prepared by one-pot simultaneous in-situ formation of AuNPs and PEDOT:PSS and was then inkjet-coated onto the SPCE. The MIP film was subsequently placed on the modified SPCE by co-electrodeposition of o-phenylenediamine and resorcinol in the presence of the antibiotic nitrofurantoin (NFT). Using differential pulse voltammetry (DPV), response at the potential of ~ 0.1 V (vs. Ag/AgCl) is linear in 1 nM to 1000 nM NFT concentration range, with a remarkably low detection limit (at S/N?=?3) of 0.1 nM. This is two orders of magnitude lower than that of the control MIP sensor without the nanocomposite interlayer, thus showing the beneficial effect of AuNP-PEDOT:PSS. The electrode is highly reproducible (relative standard deviation 3.1% for n?=?6) and selective over structurally related molecules. It can be re-used for at least ten times and was found to be stable for at least 45 days. It was successfully applied to the determination of NFT in (spiked) feed matrices and gave good recoveries.
Graphical abstract Schematic representation of a voltammetric sensor for the determination of nitrofurantoin. The sensor is based on a screen-printed carbon electrode (SPCE) modified with an inkjet-printed gold nanoparticles-poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) nanocomposite and a molecularly imprinted polymer.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号