首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of cetirizine in human urine by high-performance liquid chromatography.
Authors:M T Rosseel  R A Lefebvre
Institution:Heymans Institute of Pharmacology, University of Ghent Medical School, Belgium.
Abstract:A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏