首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Insect Protein Content Analysis in Handcrafted Fitness Bars by NIR Spectroscopy. Gaussian Process Regression and Data Fusion for Performance Enhancement of Miniaturized Cost-Effective Consumer-Grade Sensors
Authors:Krzysztof B Be&#x;  Justyna Grabska  Nicole Plewka  Christian W Huck
Institution:Institute of Analytical Chemistry and Radiochemistry, University of Innsbruck, Innrain 80/82, 6020 Innsbruck, Austria; (J.G.); (N.P.)
Abstract:Future food supply will become increasingly dependent on edible material extracted from insects. The growing popularity of artisanal food products enhanced by insect proteins creates particular needs for establishing effective methods for quality control. This study focuses on developing rapid and efficient on-site quantitative analysis of protein content in handcrafted insect bars by miniaturized near-infrared (NIR) spectrometers. Benchtop (Büchi NIRFlex N-500) and three miniaturized (MicroNIR 1700 ES, Tellspec Enterprise Sensor and SCiO Sensor) in hyphenation to partial least squares regression (PLSR) and Gaussian process regression (GPR) calibration methods and data fusion concept were evaluated via test-set validation in performance of protein content analysis. These NIR spectrometers markedly differ by technical principles, operational characteristics and cost-effectiveness. In the non-destructive analysis of intact bars, the root mean square error of cross prediction (RMSEP) values were 0.611% (benchtop) and 0.545–0.659% (miniaturized) with PLSR, and 0.506% (benchtop) and 0.482–0.580% (miniaturized) with GPR calibration, while the analyzed total protein content was 19.3–23.0%. For milled samples, with PLSR the RMSEP values improved to 0.210% for benchtop spectrometer but remained in the inferior range of 0.525–0.571% for the miniaturized ones. GPR calibration improved the predictive performance of the miniaturized spectrometers, with RMSEP values of 0.230% (MicroNIR 1700 ES), 0.326% (Tellspec) and 0.338% (SCiO). Furthermore, Tellspec and SCiO sensors are consumer-oriented devices, and their combined use for enhanced performance remains a viable economical choice. With GPR calibration and test-set validation performed for fused (Tellspec + SCiO) data, the RMSEP values were improved to 0.517% (in the analysis of intact samples) and 0.295% (for milled samples).
Keywords:near-infrared (NIR) spectroscopy  miniaturized sensor  handheld  protein analysis  partial least squares regression (PLSR)  Gaussian process regression (GPR)  data fusion  insect protein  artisanal food
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号