首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Chemiluminescence determination of tiopronin and its metabolite 2-mercaptopropionic acid in human urine by HPLC coupled with flow injection
Authors:Yining Zhao  W R G Baeyens  X R Zhang  A C Calokerinos  K Nakashima  G Van Der Weken  A Van Overbeke
Institution:(1) Faculty of Pharmaceutical Sciences, Laboratory of Drug Quality Control, University of Ghent, Harelbekestraat 72, 9000 Ghent, Belgium;(2) Chemistry Department, Laboratory of Analytical Chemistry, University of Athens, Panepistimiopolis 15771, Athens, Greece;(3) School of Pharmaceutical Sciences, Nagasaki University, 1-14 Bunkyo-machi, 852 Nagasaki, Japan
Abstract:Summary In previous pharmacokinetic studies tiopronin, a drug used for effective treatment of cystinuria and rheumatoid arthritis, and its metabolite 2-mercaptopropionic acid were analysed by conventional liquid chromatography with pre- and post-column derivatization and UV detection. Now a novel HPLC-coupled chemiluminescence-flow-injection analysis (CL-FIA) method has been developed for the determination of tiopronin and 2-mercaptopropionic acid in urine. The method is based on chemiluminescence from a Ce(IV) oxidation system sensitized by quinine, as proposed earlier by this group, and flow-injection analysis. The method, which has the advantages of high sensitivity and selectivity, simple sample treatment and prompt production of results, has also been preliminarily adapted for pharmacokinetic study of tiopronin in urine.
Keywords:Column liquid chromatography  Chemiluminescence detection  Tiopronin  Thiols
本文献已被 SpringerLink 等数据库收录!