Radon in the spa of Bizovac
Authors:J Planini?  Z Faj  B ?uveljak  V Radoli?  J Vaupoti?  I Kobal
Institution:(1) Facuty of Education, University of Osijek, POB 144, Osijek, Croatia;(2) J. Stefan Institute, Ljubljana, Slovenia
Abstract:The radon concentration in the air and water of the Bizovac spa was measured by the Radhome silicon detector and the average values were obtained as 70 Bq/m3 in the indoor pool, 40 Bq/m3 in the hotel room, 135 Bq/m3 in the closed therapeutic bathroom, but the geothermal water had a Rn concentration of 25.3 kBq/m3 and the potable one 2.7 kBq/m3. The Rn transfer factor (f) from water to air in the indoor pool and therapeutic bathroom was 10 and 40 times higher than for normal dwellings (f n=10–4), respectively. The effective equivalent dose of inhaled radon for permanent personnel under the worst conditions in the spa was 5.4 mSv/y, but visitors spending two weeks in the spa could receive the dose of 77 mgrSv.
Keywords: