Institution: | a Argonne National Laboratory, Advanced Photon Source, 9700 S. Cass Avenue, Argonne, IL 60439, USA b European Synchrotron Radiation Facility, BP 220-F-38043, Grenoble Cedex, France |
Abstract: | The absorbed-dose distributions for bremsstrahlung, incident on a tissue-equivalent phantom, were measured with LiF : Mg,Ti thermoluminescent dosimeters at two insertion device beamlines of the European Synchrotron Radiation Facility (ESRF). The measurements were carried out for two different electron beam energies of 4 and 6 GeV. The corresponding bremsstrahlung spectra and power were measured using a high-resolution lead glass total absorption calorimeter. The results are compared with similar measurements carried out at other facilities. The normalized bremsstrahlung absorbed dose in a cross-sectional area of 100 mm2, at a depth of 150 mm of the phantom, was measured as 6.1 and 3.6 kGy h−1 W−1 for the corresponding bremsstrahlung spectra of 4 and 6 GeV. |